Portable power stations from brands such as Jackery, Bluetti, EcoFlow and Anker are no longer just for camping. More UK households are buying them for power cuts. This guide covers what they do, what they’ll run and for how long, how to charge them, how the new UK plug-in solar law affects them, and whether the cost is justified.
What is a home power station?
A home power station is a large rechargeable lithium battery with a built-in inverter. The inverter turns the battery’s DC power into 230V AC, so you can plug in ordinary UK appliances. Most units also have USB-A, USB-C and 12V outputs.
Two figures matter most:
- Capacity (Wh or kWh) is how much energy it stores. It tells you how long it can run things.
- Output (W) is how much power it can deliver at once. It tells you what it can run.
Most current models use LiFePO₄ (lithium iron phosphate) cells. These are typically rated for 3,000–4,000 charge cycles before falling to around 70–80% of their original capacity. Older NMC-based units manage roughly 500–1,000 cycles. If you’re buying a unit to keep for years, choose LiFePO₄.
Why have one in the UK?
UK power cuts are usually short, but they do happen, especially in winter storms and in rural areas supplied by overhead lines. A power station is useful for:
- Power cuts: keeping the fridge, freezer, Wi-Fi, lights and phones going.
- Working from home: keeping your router and laptop online.
- Off-grid use: campervans, garden offices, allotments, events and filming.
- Tariff shifting: charging on off-peak rates such as Octopus Go or Intelligent Octopus and using the stored power at peak times. The savings are small at portable sizes, so treat this as a bonus rather than the reason to buy.
Automatic switchover: UPS and EPS mode
Many models can sit between the wall socket and your appliances, passing mains power straight through. If the mains fails, the unit switches to battery automatically.
- EPS (Emergency Power Supply) switches over in typically 10–30 milliseconds. Fridges, freezers, routers and lights won’t notice.
- True UPS (0 ms) is needed for desktop PCs and NAS drives that reboot on even a brief dip. Check the spec sheet: many units are marketed as “UPS” but actually switch in around 20 ms.
In practice, you plug the power station into the wall and plug your fridge-freezer or router into the power station. It stays charged and takes over by itself when the power goes.
Control by app: Bluetooth and Wi-Fi
Most current models can be monitored and controlled from the maker’s phone app, connecting over Bluetooth, Wi-Fi or both. The difference matters most during a power cut.
Bluetooth
- Range is short, typically around 10m and less through walls.
- It needs no internet or router, so it keeps working in a power cut.
- It’s best for setup and checking the unit when you’re nearby.
- The limitation is that you can’t check the unit from another room or while you’re away.
Wi-Fi
- It connects through your home router to the manufacturer’s cloud, so you can check and control the unit from anywhere.
- It’s best for remote monitoring, alerts and schedules.
- The power-cut catch is that when the mains goes, so does your router, unless the router is plugged into the power station. Otherwise the app falls back to Bluetooth or loses contact.
What the apps typically let you do
- Monitor battery percentage, input watts (solar, mains or car) and output watts live.
- See an estimated runtime at the current load.
- Switch AC, DC and USB outputs on or off remotely.
- Set the AC charging speed. Slower charging is quieter and gentler on the battery.
- Set charge and discharge limits, such as an 80–90% cap to prolong battery life or an emergency reserve.
- Turn UPS/EPS mode on or off.
- Set time-of-use schedules (on some models) to charge on cheap tariffs.
- Receive notifications for grid failure, low battery or charge complete.
- Install firmware updates, which sometimes add features or improve switchover.
What to check
- Whether the unit has Wi-Fi or Bluetooth only. Some budget and older models are Bluetooth-only.
- Whether it supports 2.4GHz Wi-Fi only, which is common. Setup can fail on routers that combine 2.4GHz and 5GHz under one network name.
- Whether it has full offline control. The unit should work from its own buttons and screen even if the app or the manufacturer’s servers are down.
- Whether you need an account. Most apps require registration and acceptance of the maker’s data terms.
- Whether it works with smart-home systems. Home Assistant, Alexa and Google Home support varies widely and is sometimes community-built only, so don’t rely on it unless the product page lists it.
Tip: plug your router and ONT into the power station’s EPS outlet. In a cut you keep your broadband, any cloud-based heating controls and remote app access, all for about 15–20W.
What will it run, and for how long?
You can estimate runtime with:
Runtime (hours) ≈ Capacity (Wh) × 0.85 ÷ Appliance load (W)
The 0.85 factor allows for inverter losses. The figures below are typical. For accuracy, check your appliances’ rating plates or measure them with a plug-in energy monitor.
| Appliance | Typical draw | 1 kWh unit | 2 kWh unit |
|---|---|---|---|
| Phone charge | ~15 Wh per charge | ~55 charges | ~110 charges |
| Wi-Fi router + ONT | 10–20 W | 40–80 hrs | 85–170 hrs |
| Laptop | 30–65 W | 13–28 hrs | 26–55 hrs |
| LED lights (several) | 20–40 W | 20–40 hrs | 40–85 hrs |
| TV (LED, 43–55″) | 60–100 W | 8–14 hrs | 17–28 hrs |
| Fridge-freezer | ~1–1.5 kWh/day (cycles on and off) | ~14–20 hrs | ~1–1.5 days |
| Chest freezer | ~0.5–0.8 kWh/day | ~1–1.5 days | ~2–3 days |
| Gas boiler (pump, fan, controls) | 80–200 W while firing | ~5–10 hrs of heating | ~10–20 hrs |
| Kettle (3 kW) | 2,500–3,000 W | High-output units only; drains fast | Possible, but wasteful |
Fridges and freezers: compressors draw a start-up surge several times their running wattage, so check that the unit’s surge (peak) rating can cope. Most 1,000W+ units can. A full freezer kept closed will stay frozen for roughly 24–48 hours without power, so in a short cut you may not need to power it at all.
Can it run gas central heating?
Often, yes, and in a winter power cut this is one of a power station’s most valuable uses. A gas combi or system boiler needs electricity for its fan, pump, ignition and controls, so it stops when the mains fails. Its total draw is modest, usually 80–200W.
There are some important caveats:
- A pure sine wave inverter is essential. Boiler electronics can misbehave on modified sine wave power. Reputable power stations are almost all pure sine wave, but check before you buy.
- Most UK boilers are wired into a fused spur, not a plug. You can’t simply plug the boiler into a power station. The usual solution is for a qualified electrician to fit a plug-and-socket arrangement or a proper changeover switch. Don’t do this yourself, and never back-feed a household circuit. Any work on the boiler itself must be carried out by a Gas Safe registered engineer.
- The controls need power too. Wireless thermostats and hubs such as Hive, Nest and Tado need power, and so does your router if the controls are cloud-based.
Need someone to do the work? Find a qualified electrician or Gas Safe registered engineer in our Electricians and Gas Engineers directory. For smart thermostats and hubs, see our Energy Controls and Thermostats directory.
Once the boiler is correctly wired, a 2 kWh unit can keep a typical home’s heating going through an evening-length outage.
Charging options
1. Mains (plug-in)
This is the fastest method. Many current units charge from 0–80% in about an hour using their built-in AC charger. Charge on an off-peak tariff and keep the unit topped up, ready for a cut.
2. Solar
Portable folding panels (100–400W) or fixed rigid panels connect through the unit’s built-in MPPT controller.
- The UK reality: a 200W panel might deliver 0.6–1 kWh on a good summer day, but only 0.1–0.3 kWh on a dull December day. In winter, treat solar as a top-up, not a full recharge.
- Check the unit’s maximum solar input in both watts and volts, and whether it accepts two solar inputs.
For panels and installers near you, browse our Solar Power directory.
3. Car (12V socket)
You can charge from your car’s 12V socket while driving.
- It’s slow, typically 100–120W, so a 1 kWh unit takes around 8–10 hours.
- It’s good for staying topped up on a trip, but impractical as your main charging method.
- Some brands sell alternator chargers for campervans, for example EcoFlow’s 800W unit, which charge much faster.
- Don’t idle a petrol or diesel car for hours just to charge a battery. It’s inefficient, and leaving an engine running unnecessarily while parked can breach the Highway Code.
4. EVs with vehicle-to-load (V2L)
Some EVs, including the Kia EV6, Hyundai Ioniq 5 and MG4, have V2L sockets that output around 3.6 kW. That’s enough to recharge a power station quickly during a long outage, or to run appliances directly.
What about the new plug-in solar law?
Since 27 August 2026, plug-in (“balcony”) solar has been legal in England, Scotland and Wales under SI 2026/848, with Northern Ireland expected to follow. It’s worth understanding how this relates to power stations, because the two are often confused.
What the law allows
- Complete, factory-built kits only, meeting the DESNZ Interim Product Specification and listed as compliant on the ENA type test register. Putting a system together from your own components does not qualify.
- A maximum of 800 VA AC output, through a moulded BS 1363 plug with a 5A (or lower) fuse.
- A free G98 notification to your Distribution Network Operator within 28 days of connecting. Currently only one plug-in device is allowed per household.
- No electrician is needed for a compliant kit.
- Mounting restrictions apply, and you need landlord or freeholder consent before fixing panels to the building. Planning permission isn’t generally needed for systems of up to 800W, but listed buildings and conservation areas have extra restrictions.
- The government’s headline figure is savings of up to £110 a year. Actual savings depend on orientation, shading and how much of the output you use yourself.
How power stations fit
- Batteries are excluded from the plug-in route. Kits with integrated storage, and power stations that export into house wiring, fall outside SI 2026/848, whatever the marketing says. Such systems can still be connected through a hardwired installation by a registered electrician, with G98 notification.
- Normal power station use is unaffected. Charging a Jackery or Bluetti from its own panels, the mains or a car, then plugging appliances into the unit, never involves feeding the grid. EPS pass-through is fine for the same reason.
- Never feed house circuits from a socket. Using a male-to-male “suicide lead” remains dangerous and illegal.
- Plug-in solar kits don’t help in a power cut. Their micro-inverters shut down when the grid fails (anti-islanding), so they produce nothing during a cut.
For hardwired battery or solar installations, see our Electricians and Gas Engineers and Solar Power directories.
In short: a plug-in solar kit cuts your bills, and a power station with its own panels keeps your fridge and boiler running when the grid goes down. They complement each other rather than compete.
Costs (UK, late 2026)
Prices change often and drop sharply during sales such as Black Friday and Prime Day. These are typical street-price ranges:
| Size | Typical capacity | Typical price | Good for |
|---|---|---|---|
| Small | 250–500 Wh | £150–£350 | Phones, laptops, router, lights |
| Mid | 1–1.5 kWh | £400–£900 | Fridge-freezer, router and lights for a day |
| Large | 2–3 kWh | £900–£2,000 | Boiler, freezer, fridge, comms |
| Expandable / home | 3–10+ kWh | £2,000–£6,000+ | Whole-circuit backup via a transfer switch |
On top of the unit itself, budget for solar panels (roughly £150–£500 per 200–400W panel) and electrician costs if you want to connect it to specific circuits.
Lifetime cost per stored kWh: an £800, 1 kWh LiFePO₄ unit rated for 3,000 cycles works out at roughly 27p per kWh cycled, before the cost of the electricity itself. It won’t pay for itself through tariff shifting. Its value is resilience, not savings.
Check current UK prices and offers from Jackery and Bluetti, or find UK suppliers in the EnergyBook Batteries and Power Stations directory.
Safety and installation
- Never back-feed your home from a power station through a wall socket.
- Powering house circuits requires a changeover or transfer switch fitted by an electrician to BS 7671. Find one in our Electricians and Gas Engineers directory.
- Use the unit indoors, in a ventilated spot away from heat sources.
- Check for UKCA or CE marking and a UK-plug charger, and avoid grey imports.
Buyer’s checklist
- ☐ Capacity: total the Wh per day of your essential loads, and add a margin.
- ☐ Continuous output above the combined load of everything you’ll run at once.
- ☐ Surge rating high enough for fridges, freezers and pumps.
- ☐ LiFePO₄ chemistry.
- ☐ EPS/UPS switchover time: about 20 ms is fine for most loads; 0 ms for PCs and NAS drives.
- ☐ Pure sine wave output, essential for boilers.
- ☐ Solar input (watts and volts), and whether it takes two inputs.
- ☐ 12V car charging included.
- ☐ App control: Wi-Fi as well as Bluetooth, and full offline operation.
- ☐ Expandable with extra batteries.
- ☐ Warranty: 5 years is now common.
- ☐ Fan noise: matters if the unit lives in a kitchen or bedroom.
Final thoughts
For most UK homes, a 1–2 kWh LiFePO₄ unit with EPS mode and Wi-Fi app control is the sweet spot. It keeps the fridge cold, the broadband on and the phones charged, and with a little electrician work it can keep the gas boiler running through a winter outage. If you’re considering much larger expandable systems, compare them with a dedicated hardwired home battery, especially if you already have rooftop solar or plan to add it.
Ready to compare models? Browse the Jackery UK range and the Bluetti UK range. Both include LiFePO₄ units with UPS mode, solar input and app control.
Affiliate disclosure: energybook.co.uk may earn a commission from links on this page, at no extra cost to you.